PRODUCTS
You are here: Home » Products » Power Factor Correction » Capacitor Bank » Power Factor Correction » Capacitor Bank » Intelligent Active Static Var Generator Panel Svg Series

Intelligent Active Static Var Generator Panel Svg Series

The static var generator (SVG) panel serves as the ultimate solution for high-precision power quality in modern industrial grids. This professional reactive power compensation equipment effectively eliminates voltage flicker while stabilizing the entire electrical distribution network. Furthermore, this Power Factor Correction Device utilizes high-speed IGBT switching to ensure consistent voltage at the receiving end. Consequently, our advanced technology delivers superior reactive power management compared to traditional mechanical switching systems.
 
Rated Voltage:
Availability:
facebook sharing button
twitter sharing button
line sharing button
linkedin sharing button
whatsapp sharing button
sharethis sharing button
  • SVG

  • Giantele

  • 400V

  • 50Hz

  • PVOC/SONCAPISABS/COC/COI/CRCC/GCC

  • Three Phase

  • 1 Piece

  • 50 kvar, 75 kvar, 100 kvar, 200 kvar

Overview 

The static var generator (SVG) panel serves as the ultimate solution for high-precision power quality in modern industrial grids. This professional reactive power compensation equipment effectively eliminates voltage flicker while stabilizing the entire electrical distribution network. Furthermore, this Power Factor Correction Device utilizes high-speed IGBT switching to ensure consistent voltage at the receiving end. Consequently, our advanced technology delivers superior reactive power management compared to traditional mechanical switching systems.


Applicable occasion

1.Hoists, rolling mills and other heavy industry equipment (typical impact loads for mining & metallurgical sectors) have the following grid impacts:

  • Large reactive power impact, causing grid voltage fluctuations, severe interference to other equipment operation and reduced production efficiency;

  • Low power factor, incurring high monthly reactive power penalties;

  • Harmonics from partial equipment, endangering grid safety.


2.Oil and gas drilling platform power supply systems (main loads: winches, turntables, mud pumps etc.) are typical impact loads under drilling-specific working conditions, with the following grid impacts:

  • Large reactive power impact and low power factor;

  • High current harmonics;

  • Severe voltage fluctuation & high voltage distortion rate, affecting power supply for control systems, PLC, logging instruments and other equipment.


Product Features


  • Millisecond Response Speed:This system completes the entire reactive power compensation cycle in less than 10 milliseconds.

  • Cost-Effective Hybrid Design:This power factor correction capacitor bank merges SVG speed with traditional LC units to save costs.

  • Advanced Harmonic Suppression:The capacitor bank effectively filters out harmonics up to the 13 times with over 97% accuracy.

  • Precise Dynamic Var Control:Continuously monitors and adjusts reactive power output to maintain stability and efficiency during load variations.

  • Reliable Safety Features:Each capacitor compensation cabinet includes internal safeguards against overvoltage and three-phase current imbalance.

  • Intelligent System Monitoring:We integrate this reactive power compensation equipment with RS485 and TCP/IP protocols for remote data access.

Technical parameters of the main equipment

InputRated voltage380V (allowable fluctuation range-40% ~ +20%)
Rated frequency50 ± 2Hz
Compensation capacity50 kvar, 75 kvar, 100 kvar, 200 kvar, Parallel expandable capacity
Performance
indicators
Overall machine efficiency≥ 97%, excess capacity is compensated according to maximum capacity
CT RequirementsThree CTs, accuracy level 0.5 or above, secondary current 5A
Range of compensationInductive reactive power and capacitive reactive power can be continuously replenished
Switching frequencyAverage 20KHz
Neutral filtering capability3 times phase line current
Response time40uS
Full response time10mS
Self-diagnostic functionFault self-diagnosis, automatic switching, automatic restart
Compensatory capacityFull compensation when it is within the equipment capacity, and the time limit exceeding the equipment capacity is defined as the rated compensation capacity
Protection functionOvercurrent, power grid overvoltage, undervoltage, overheating, bus overvoltage,undervoltage, short circuit, fan failure, power failure and current limiting protection, etc.
Display data and records

1. Voltage and current, power factor, THD and other parameters of each phase;
2. Power grid, load current waveform, three-phase voltage waveform;
3. Three-phase IGBT temperature display:
4. Operation mode setting and parameter setting

Communication interfaceRs485, Ethernet
Communication protocolModbus discussion
Environmental
Conditions
Man-machine interface5-inch or 10-inch touch screen
Ambient temperature-10C ~ +45C
Elevation< 2 km, higher altitude can be derated
Level of protectionIP20
StructureCooling methodIntelligent air cooling
Installation methodWall-mounted, drawer-mounted, whole cabinet drawer-mounted