| Rated Voltage: | |
|---|---|
| Availability: | |
GGJ
Giantele
400V
50/60Hz
IP40
PVOC/SONCAPISABS/COC/COI/CRCC/GCC
Three
1 Piece
up to 600kvar
Overview
Automatic Power Factor Correction (APFC) panel optimize your electrical network by stabilizing reactive power and minimizing energy waste effectively. Furthermore, this advanced capacitor bank lowers line losses while increasing the actual load capacity of transformers significantly. Also, the high-quality power capacitor prevents harmonic amplification because it uses specific reactors to protect your system. This automatic power factor correction equipment meets international IEC standards to ensure reliable and safe power distribution.
Environmental Conditions
Temperature stability:Maintain pfc performance in ambient temperatures between -5℃ and +40℃ for optimal long-term reliability.
Humidity control:Ensure power factor correction stability by keeping the relative humidity below 90% at 20℃ because moisture affects components.
Altitude constraints:Install the equipment at altitudes under 2000m so the insulation protects the internal circuits against electrical failure.
Environmental safety:Keep the area free from conductive dust or corrosive gases because these substances damage sensitive electrical parts
Product Features
Universal compatibility:The substation capacitor bank integrates seamlessly with standard low-voltage cabinets to offer strong general performance.
Flexible compensation modes:Our capacitor bank in substation supports multiple connection types so it adapts to unstable reactive power loads easily.
Diverse communication methods:Monitor the power factor correction capacitor via RS-485 or wireless modules because the device supports long-distance data transmission.
Safe zero-crossing switching:pfc capacitor uses voltage crossing triggers to eliminate inrush current and protect the overall system grid.
Maintenance-free design:The system provides a service life exceeding 100,000 hours so users save on long-term replacement costs.
Effective harmonic filtering:Specific reactors prevent harmonic amplification while cleaning the power supply for industrial and mining enterprises specifically.
Enhanced energy efficiency:Because the unit improves power factors, it delivers significant energy-saving effects for civil buildings and factories.
| Item | Units | Value |
| Rated Voltage | V | 220/400/690 |
| Rated Frequency | Hz | 50/60 |
| Applicable Voltage Range | 0.85-1.1 times the rated voltage | |
| Maximum Permissible Current | 1.3 times the rated Current | |
| Control Loop Quantity | 1-16 loops | |
| Working Mode | automatic and continuous working |