Overview
The Ring Main Unit delivers a new generation of environmentally friendly power distribution for 12kV three-phase AC systems. This advanced solid insulated switchgear (SIS) uses fully sealed epoxy resin encapsulation, eliminating SF6 gas entirely. As a result, this sf6 free rmu operates safely across extreme temperatures, coastal humidity, and high-altitude plateau environments. Furthermore, its modular architecture supports both indoor and outdoor deployment in a ring type distribution network, and is suitable for various application scenarios.
Product Features
SF6-Free Solid Insulation:This electrical rmu uses epoxy resin to fully encapsulate live components, eliminating greenhouse gas risk entirely.
Zero-Maintenance Full Sealing :The Medium Voltage Switchgear adopts APG-process epoxy bushings with silicone rubber sealing at every connection point.
Flexible Modular Design:This mvsg supports free combination of circuit breaker, load switch, and combined apparatus units per project need.
Five-Prevention Interlocking Safety:Every Electrical Switchgear module meets five-prevention interlock requirements with visual isolation-fracture windows for safe verification.
IAC-Compliant Arc Fault Protection:Each rmu switchgear cabinet features a directional pressure-relief valve that safely discharges internal arc faults into the cable trench.
Smart Grid Ready:This Medium Voltage Ring Main Unit supports remote control, remote measurement, and remote communication via an intelligent controller interface.
High-Performance Vacuum Breaking:The Power Factor Correction Device—combined with copper-chromium contacts and R-shaped longitudinal magnetic field technology—achieves a 25kA short-time withstand current rating and 10,000 mechanical operations for the circuit breaker.
1.Urban Distribution Substations & Compact Secondary Stations
Challenge: Space-constrained city centers require SF₆-free gear to meet air quality mandates (e.g., London LEZ).
SIS Role:
Zero-gas design eliminates F-gas reporting/taxes (EU 517/2014)
40% smaller footprint vs. AIS, fits basements/car parks
IP67-rated solid barriers prevent flashovers in polluted/damp environments
2.Hyperscale Data Centers & Edge Computing Sites
Challenge: Strict PUE targets, zero tolerance for SF₆ leaks near critical IT loads.
SIS Role:
SF₆-free insulation aligns with RE100 commitments (Google/Amazon)
V0-rated fire-resistant epoxy eliminates arc-flash propagation risks
-40°C to +65°C operation ensures server-farm microclimate stability
3.Heavy Industrial Plants (Steel/Mining/Chemical)
Challenge: Conductive dust/corrosive vapors degrade conventional switchgear.
SIS Role:
Hermetically sealed modules block salt, sulfide & metal particulates
IEC 62271-3 Class 2 seismic resilience for high-vibration zones
No SF₆ gas monitoring, 35% lower OPEX vs. GIS
4.Port Electrification & Offshore Renewables
Challenge: Salt spray/100% humidity trigger insulation failures.
SIS Role:
Corrosion-proof encapsulation passes ISO 9227 salt-mist testing
Pressurization-free design avoids explosion risks at sea level/altitude
Shock/vibration resistance for floating solar/wind installations
5.Hospitals & Tunnel Power Networks
Challenge: Critical infrastructure requires fire-safe, non-toxic gear.
SIS Role:
Zero-toxicity decomposition (even during arc faults)
Limited ventilation compatible for underground deployments
Passive cooling operation eliminates HVAC dependency
| Item | Unit | Data | |
| Rated voltage | kv | 12 | |
| Rated current | A | 630 | |
| Rated short-time withstand current (4s) | kA | 25 | |
| Rated peak withstand current | kA | 50 | |
| Rated short-circuit closing current (peak) | kA | 50 | |
| Rated active load breaking current | A | 630 | |
| Rated closed loop breaki ng current | A | 630 | |
| Rated cable charge breaking current | A | 10 | |
| Rated breaking transfer current of combined appliances | A | 3700 | |
| 1 min power frequency withstand voltage | Phase- to-phase, phase -to- ground, vacuum breaking | kv | 42 |
| Insulation breaking | kv | 48 | |
| Lightning impact withstand voltage | Phase- to-phase, phase -to- ground, vacuum breaking | kV | 75 |
| Insulation breaking | kv | 85 | |
| Mechanicallife | Circuit breaker | Time | 10000 |
| Insulation knife, grounding knife | Time | 3000 | |
| Protection grade | IP4X | ||
| Shell protection grade | IP4X | ||
| Partial discharge | PC | ≤20(Measured at 1.2Ur) | |
| Potential transformer capacity kVA | Fuse model | Fuse rated current (A) | |
| Voltage class 12kV | Voltage class 63kV | ||
| 100 | XRNT-12kV | 10 | 16 |
| 125 | XRNT-12kV | 10 | 20 |
| 160 | XRNT-12kV | 16 | 20 |
| 200 | XRNT-12kV | 20 | 25 |
| 250 | XRNT-12kV | 25 | 31.5 |
| 315 | XRNT-12kV | 31.5 | 40 |
| 400 | XRNT-12kV | 40 | 50 |
| 500 | XRNT-12kV | 50 | 63 |
| 630 | XRNT-12kV | 63 | 80 |
| 800 | XRNT-12kV | 80 | 100 |
| 1000 | XRNT-12kV | 100 | 125 |
| 1250 | XRMT-12kV | 125 | - |